Polycarbonate installation and maintenanse

Installation guidelines

  • Note the thermal expansion of sheets when fixint it to sub-construction (~3 mm for every 1 m of length)
  • Wall direction should match slope and should be vertical
  • Bending direction should be in transverse section of walls
  • Wash sheets with water and soft rag
  • Do not clean with abrasives or sharp tools, as far as solvents of acids
  • Close open walls with sealing and anti-dust tapes. U-profiles also should be used.
  • To fix sheet to your construction, drill holes larger than screw diameter to provide thermal expansion. Screws should have a rubber band to protect cameras from moisture.
  • Do mot place screws closer than 40mm to sheet edges.

Installation guidelines

Distance between rafters, m4 mm6mm8mm10mm16mm
0,5030
801401800400
0,6060
100
120350
0,70– 6080200
0,90– – 60100
1,00– – – 60

Multiwall Polycarbonate Properties

 

Thickness
mm

CellsU-value W/m2KLight transmission %
clear/bronze
Aclustical isolation dBMin bending
radius m
413,982 / –180,60
613,684 / 60180,90
813,281 / 65181,20
1012,884 / 44201,50
1622,373 / 25222,40
25S21,557 / 15225,30